Enable Alarm Management
You can configure the system to send alarm notifications (traps) to an SNMP agent or an email account. You can also specify whether a notification is generated for each alarm, for all alarms of a particular type (Information, Warning, etc.), or for all alarms together. The first option results in the most notifications; the last option results in the fewest notifications.
Configure Alarm Management
To enable alarm management:
-
From the Main Menu, select (S) System Maintenance, and then (T) Alarm Setting and Management.
-
Select (A) Alarm Setting.
-
Select a notification method:
-
For SNMP notification, select (A) SNMP Settings.
-
For Email notification, select (B) Email Settings. Note: You can configure both methods.
-
-
In the Alarm SNMP Setting or Alarm Email Setting menu, select option (A)to enable notification and enter:
-
1 to enable OR
-
0 to disable
-
-
Select option (B) to set the Sending Option and enter one of the following:
-
0 to report every alarm type
-
1 to report only once (if an alarm is raised when there is no existing active alarm)
-
2 to report every alarm individually
-
-
Select option (C) to set Sending Severity and enter one of the following:
-
1 for Informational alarms
-
2 for Warning alarms
-
3 for Minor alarms
-
4 for Major alarms
-
5 for Critical alarms
-
-
For Email notification, select option (D) to set Email Addresses for alarm messages. Enter one or more email addresses separated by commas.
-
Exit to save your changes.
-
Alarm management emails received in the Outlook environment may not have the proper heading format because the "Auto Remove Line Breaks" feature in Outlook is enabled. To correct this problem, search for article # 287816 at http://support.microsoft.com/.
-
If you enable SNMP Notification, you must configure the SNMP service on the Mitel Standard Linux (MSL) server. For instructions, see Configure SNMP on MSL. For additional information, refer to the Mitel Standard Linux Installation and Administration Guide .
Report and Manage Alarms:
You can manage alarms and produce reports for active alarms, cleared alarms, or all alarms.
To manage alarms:
-
From the Main Menu, select (S) System Maintenance, and then (T) Alarm Management.
-
Select (B) Alarm Report and Management.
-
Select one of the following options:
-
Option (A) to Report and Manage Active Alarms
-
Option (B) to Report and Manage Acknowledged Alarms
-
Option (C) to Report and Manage All Alarms
-
Option (D) to report Alarm status
-
-
Do one or more of the following:
-
Select Option (A) to display a report of each alarm category
-
Select option (B) to acknowledge a selected alarm or option (C) to acknowledge all alarms, as required
-
Select option (D) to delete a selected alarm or option (E) to delete all alarms, as required
-