CESID

System/Sub-System

MiVoice Business: Software

Description

This alarm indicates that the system has detected a CESID assignment problem in an IP device that has automatic CESID updating enabled in the CESID Assignment form.

Alarm Status

Minor.

Possible Cause Corrective Action
  • A new or known IP device has registered, but no CESID is available for the device.
  • A device has moved, and no CESID is available for the device at its new location.
  • At system startup, one or more IP devices that have Automatic CESID Updating enabled but have no CESIDs assigned to them.
  • A new or known device has registered, but the CESID in the CESID Assignment form is different from the CESID in the L2 to CESID Mapping form.

Assign CESIDs in the CESID Assignment form or the L2 to CESID Mapping form.

Once all DN CESID assignments are made, the system will clear the alarm.