Resilient ACD
Go to |
Do this |
|
|
|
In the ACD Path page, program the following settings:
Note: The voicemail mailbox is automatically managed by Management Portal in the non-resilient case. |
General mailbox
-
The MiVoice Business platform does not natively support resilient ACD paths. The calling number which lands on a path is not consistent when the call lands on the Secondary compared with the Primary Path Controller.
-
To work around the issue, a named tag hunt group is used to provide a consistent calling number to land on a single mailbox independent if the call came through the Primary or Secondary Path Controller.
Example programming:
-
Create a mailbox in EMEM with mailbox number 4000 on both the Primary and Secondary Path Controller
-
Create a resilient Name Tag Hunt Group = 3000
-
Set the Name Tag= 4000
-
Create a member 3001 (MWI for the mailbox will be assigned to the first member of the group)
-
Use hunt group 3000 as the answer point in the ACD path for mailbox 4000.
-
Set MWI keys to monitor extension 3001 for the MWI for mailbox 4000.